首页 > 技术动态 > 正文

西安张航复制水野教授实验取得重复性超热
2020-04-18 16:36:02   来源:冷聚变世界   评论:0 点击:

西安的张航工程师给笔者发来了最新的实验报告,他在多次实验后最近取得了突破性进展,成功的实现了冷聚变过热的可重复性。

实践是检验真理的唯一标准
Practice is the sole criterion for testing truth
想,都是问题
Think, it's all a problem.
干,才有答案
Only by doing can we have an answer.
撸起袖子加油干
The nation remains mobilized for brand new endeavors.


张航    秋然实验室
Email:715469127@qq.com

 


整套实验装置图

 
复制水野教授的实验,采用的金属钯涂布在镍网上,以下是准备的材料以及涂布后效果:


钯棒购买自Alfa Aesar

镍网 180目  购买自安恒丝网

未涂布金属钯的镍网

涂布金属钯后的镍网





反应器的外观示意图


反应器外观图



Seebeck 量热器内的反应器
 


安装好的量热器


多功能直流电源

输入电功率计

  

空白试验

容器抽真空,进行空白试验
Vacuum evacuation of container for blank test


 
Blank test of 20190806      
Seebeck voltage Input power Calculated power excess power
0 0 0.042 0.042
3.819 178.18 178.0009764 -0.179023558
5.529 255.09 255.0557242 -0.034275798
7.347 335 335.1940223 0.194022298
9.169 413.83 413.664924 -0.165075958
 
 
量热器内温度
Temperature in calorimeter
冷却水出水温度
Cooling water outlet temperature
容器中心温度
Central temperature of container
加热功率
heating power(W)
辉光放电电压
Glow discharge power(W)
环境温度
ambient temperature
41.6 33.6 322 164.2 0 27
49 36.9 351.9 241.2 0 26.7
56.9 40.5 404.9 321.3 0 27.3
64.7 43.9 450.1 400.2 0 27.5
 
 

容器压力
Vessel pressure(kpa)
塞贝克
seebeck
原件电压
Original voltage
冷却水进水温度
Cooling water inlet temperature
容器外壳温度
Container Shell Temperature
风机的电流
Current of Fan
风机的电压
Voltage of Fan
0 3.819 25.5 226.1 1.44 9.71
0 5.529 25.5 299.9 1.43 9.72
0 7.347 25.6 355.8 1.41 9.72
0 9.169 25.6 406.5 1.4 9.74
 


第一次,持续时间2.5小时,最大多余功率9瓦,总热量44千焦
For the first time, it lasts 2.5 hours, with a maximum excess power of 9 watts and a total heat of 44 kJ.



第二次,持续时间2.5小时,最大多余功率4瓦,总热量20千焦
The second time, lasting 2.5 hours, maximum excess power 4 watts, total heat 20 kJ
 


第三次,持续时间2.5小时,最大多余功率9.6瓦,总热量47千焦
Third time, duration 2.5 hours, maximum excess power 9.6 watts, total heat 47 kJ

 


充入的氘气1.5毫升0.3MPa,约0.0002摩尔,化学能约60焦耳,测到的多余热量远远大于化学能。
The added deuterium gas is 1.5 ml 0.3 MPa, about 0.0002 mole, and the chemical energy is about 60 joules. The measured excess heat is much larger than the chemical energy.
 
同样情况下,将容器抽真空,充入1.5毫升0.3MPa氩气,未观察到多余热量
Similarly, the container was vacuum-pumped and filled with 1.5 ml 0.3 MPa argon. No excess heat was observed.


2020年4月对实验进行改进
Improved experiment in April 2020
 
容器内部结构进行改进
Improvement of internal structure of vessel
用镍丝制做加热电阻丝
Making heating resistance wire with nickel wire
镍丝制作螺线管
Solenoid made of nickel wire
镍丝直径0.5mm,长度10米,电阻2.6欧姆
Nickel wire diameter 0.5mm, length 10m, resistance 2.6ohm



 

镍丝螺线管状电阻丝


碳化硅加热器炉膛


碳化硅炉膛外包涂钯镍网300克,涂钯量0.3克,中心安装K型热电偶
The silicon carbide furnace is coated with 300g of palladium nickel mesh and 0.3g of palladium. The K-type thermocouple is installed in the center




容器组装完成后,放入量热器,连接管路和电线
After the container is assembled, put in the calorimeter, connect the pipeline and electric wire
抽真空
Vacuum pumping
充入氘气500帕
Deuterium gas 500 pa
维持热平衡
Maintain heat balance
无多余热量
No excess heat
然后抽真空5分钟,充入氘气500帕
Then vacuum for 5 minutes and fill 500 PA with deuterium gas
可以看见有一个热脉冲
You can see a thermal pulse
重复进行
Repeat
每次都可以看见热脉冲
Heat pulse can be seen every time

 
数据如下
The data are as follows

 
4月11日数据
April 11 data

 


4月15日数据
April 15 data

 




从以上数据可以看出
As can be seen from the above data
每做一次抽真空5分钟然后充氘气,可以看见一个多余热量脉冲
After vacuumizing for 5 minutes and then filling deuterium gas, you can see an extra heat pulse
多余热量脉冲可以持续2小时
Extra heat pulse can last for 2 hours
现象可以重复
Phenomenon can be repeated
现在仍在继续重复这个现象
This phenomenon continues to be repeated

另:附上日本水野教授实验报告,有兴趣的朋友可以参阅。




 
冷聚变世界
2020年4月18日




 
 

相关热词搜索:张航,水野,冷聚变,LENR,

上一篇:Pd(Pt)-LiOD+D2O开式电解系统的一次量热
下一篇:氢(氘)通量容器异常放热实验小结 (张航)

分享到: 收藏